ALLIED FOAM TECH
CORP. (SINCE 1994) Best Fire Rated Foam Products per ASTM-E119 Test |
|
Recent News February, 2023 (by Advanced Market Analysis Research & Media LLP in evaluating market size, trend, and forecast for global foamed concrete market to 2027) "Allied Foam Tech was selected as the key player in US for the infrastructure development in the global foam concrete market. 1. Allied Foam Tech has been awarded by USCA as the best chem machinery other manufacturer in Montgomeryville, Pennsylvania in 2015, 2014, 2013, and 2011-2009. 2. Allied Foam Tech was awarded a 2016 Gold Medal in Material Science and a 2014 Silver Medal in Applied Technology from EDISON AWARDS |
|
Allied fire barrier foam has the highest compressive and
bending strengths vs autoclaved & cast-in-place foam cement |
| Cement Composite | Cure Condition | Density | Compr. Strength | Bending Strength |
| AFT Fire Barrier Foam I | RT | 35 pcf | 900 - 1,000 psi | 370 - 500 psi |
| AFT Fire Barrier Foam II | RT | 35 pcf | 650 - 750 psi | 300-350 psi |
| AFT Portland Cem I/II | RT | 35 pcf | 400 - 450 psi | 100-200 psi |
| Autoclaved Concrete | Autoclaving | 35 pcf | 600 - 700 psi | 100 psi(?) |

|
Allied fire barrier foam has the highest fire rating per
ASTM-E-119 Test against fire rated X-gypsum boards |
![]() |
|
Allied fire barrier foam has twice or better fire ratings per
ASTM-E-119 Test over all fire rated intumescent coatings |
![]() |
![]() |
|
OTHER HIGHLIGHTS |
|||||||||||||||||||||
|
HIGHLIGHT - JANUARY, 2016 (World Trade Center Phase II Project, New York) Versatile Compact Foam Cement Mixing Pumping Setup - High Mobility with Good Output |
|||||||||||||||||||||
|
|||||||||||||||||||||
| Landscape Architechture on the Roof - An application with allied low slump foam cement | ||||||||
| Harvard University - NorthWest Science Building, 530,000 ft2 multidisciplinary research facility | ||||||||
| The World's 1st Low Slump Geotechnical Roof Fill used Allied's Cement Composite Design, Foam Products & Machinery. | ||||||||
|
The award winning facility places more than half the total square footage of the facility below grade, and incorporates three functioning green roofs. The south facade of the Northwest Science Building defines a new South Yard, equipped with low landscape furniture. The yard is a green roof over extensive basement levels, with skylights bringing daylight into the underground areas. |
||||||||
|
||||||||
| (Pre-project mockup work by Allied Foam Tech is shown below) |
![]() |
![]() |
![]() |
![]() |
| Mixing & Pumping of High | Applying of High Slump Loss | Finished Foamed Cement Crown | Cross-section of |
| Slump Loss Foam Cement | Foam Cement on 1 Vertical/4 Horizontal Slope | On Highly Sloped Geofoam | Landscape after ~ 1 year |
-
With densities from over 1,450 kg/m3
(90 pcf) to as low as 48 kg/m3 (3 pcf) for
geotechnical engineering
& landscape architecture,
lightweight concrete roof deck,
lightweight wall and floor panels
partitions
lightweight concrete blocks
insulative cinder block inserts.
-
High flexural strength, good Mandrel bending
behavior without cracking, good adhesion, exterior durability and
excellent water resistance.
-
Allied pervious
& non-pervious foamed cement are capable for waste
encapsulation, immobilization, soil stabilization and leachate filtration. Allied
long lasting foam, applied as a surface cover on landfill sites and effluent ponds and lagoons, will effectively suppress
noxious odors, vapors, litter and vectors, avoiding serious environmental issues.
-
with densities as low as 23 kg/m3
(1.5 pcf) for fabrication of insulative and high temperature resistant ceramic
foams.
-
Allied chemically engineered open and closed pore properties
within their cell structure are very similar to that
of urethane and polystyrene foams, but
without their associated poor fire resistance, yet with
outdoor durability and great cost advantage.
-with excellent strength and thermal shock resistance for fabrication of durable firebricks
used as high performance insulative materials for kilns and incinerators.
- Flexible
and very light (< 1.5 pcf or 24 kg/m3). Various geopolymer foam
composites can achieve insulative value R > 3.8 per inch and fire
resistance.
-
Using a foamable mixture as an expansion agent permits application of a
controlled film thickness with improved resin distribution and penetration
into the fabric fibers.
-
Using adhesives, based on Allied's foam system, will reduce adhesive consumption and
prevent adhesive absorption by porous substrates.
-Specially formulated foam from Allied can be used as long
duration fire fighting barriers for the containment of forest fires.